ConstantIntensityRegressor¶
- class flexparameterize.regression.constant.ConstantIntensityRegressor¶
Fits the mean energy intensity of a unit from paired flow and power data.
The simplest zero-degree-of-freedom fit: one input, one output, one coefficient. Rows where either side is null, or where the flow is zero, are dropped, and the coefficient is the mean of the per-row ratios,
mean(power / flow)— not a least-squares slope. The mean ratio weights every operating point equally, which is the behaviour an operator expects from an “average kWh per m^3” number, and it recovers a noise-free data set exactly (which is what the round-trip invariant asserts). A least-squares slope through the origin would weight high-flow points more heavily.Fit results are stored on the instance.
- coefficient¶
The fitted intensity, in the ratio of y’s units to X’s (kW over m^3/hr, i.e. kWh/m^3).
- n_samples¶
Number of rows the fit used, after dropping.
- metrics¶
{"r2": ..., "rmse": ...}ofcoefficient * flowagainst the observed power.
- data_window¶
(first, last)index value of the rows used.
- input_variable¶
Column name of the fitted input.
- output_variable¶
Column name of the fitted output.
Example
>>> import pandas as pd >>> flow = pd.DataFrame({"flow_in": [1.0, 2.0, 4.0]}) >>> power = pd.DataFrame({"power_electrical": [0.5, 1.0, 2.0]}) >>> ConstantIntensityRegressor().fit(flow, power).coefficient 0.5
- fit(X: DataFrame, y: DataFrame) ConstantIntensityRegressor¶
Fit the mean energy intensity of
yagainstX.- Parameters:
X – A one-column
DataFrameholding the flow.y – A one-column
DataFrameholding the power, sharingX’s index.
- Returns:
self, fitted.- Raises:
FlexDataError – If either side is not a
DataFrameor does not hold exactly one column, or no row survives dropping nulls and zero-flow rows.
- to_fit_result() FitResult¶
Return this fit as the shared
FitResultshape.- Returns:
The coefficient under
COEFFICIENT_NAME, alongside the fit’s metrics, sample count and data window.- Raises:
FlexDataError – If
fit()has not been called.
- to_surrogate_spec(*, input_units: str = '', output_units: str = '') SurrogateSpec¶
Return the fit as a persistable
SurrogateSpec.The one place a constant-intensity fit becomes a spec, which
apply_to_model()consumes. Built throughmake_spec(). A constant intensity sets a process parameter rather than swapping a Constraint, so unlike a real surrogate’s declared units, these are recorded for documentation, not enforced by a build.- Parameters:
input_units – Units of the fitted input column, as a string (the caller reads them off the model’s registered variable).
output_units – Units of the fitted output column.
- Returns:
A
SurrogateType.CONSTANT_INTENSITYSurrogateSpeccarrying the coefficient underCOEFFICIENT_NAMEand the fitted column names.- Raises:
FlexDataError – If
fit()has not been called.