The config schema

flex-pse is config-driven. A whole model, its time horizon, property packages, costing, plants, units, operating logic and fixed variables, can be written as one version-controlled JSON file, the spec, and built from it. Building in Python stays fully supported, and the two meet in a loop:

code ──emit_model──► spec (JSON) ──build_model──► model
  ▲                                                 │
  └──────────── same model, compared ───────────────┘

emit_model() reads the spec a live model was, or could have been, built from. build_model() turns a spec back into a model. A model that survives the loop unchanged is fully described by its file: it can be reviewed, diffed, rebuilt somewhere else and changed without touching code. Round-trip a model walks through the loop end to end.

The spec

A spec (FlowsheetSpec) is a header (the schema_version, the model name, and the fix policy described below) and one flat list of elements. Each element has a kind. The rules:

  • Names are full component paths. A unit named "waterfacility.tank" is built as model.waterfacility.tank, so its parent, the plant "waterfacility", must be an element too.

  • Elements refer to each other by name. A connection goes to "waterfacility.plant.inlet"; a status element names the unit "plant.ro" (every member of an indexed unit) or "plant.ro[0]" (one).

  • File order is irrelevant. The build sorts elements by kind, depth and name. Shuffling the list builds the same model, component for component.

So this scrambled spec is valid. It is the frozen API example, with the objective listed before the units it optimizes and the plant after the units inside it:

{
  "schema_version": "0.1.1",
  "name": "waterfacility",
  "elements": [
    {"kind": "unit", "name": "waterfacility.plant",
     "unit_model_class": "ConstantEnergyIntensityModel",
     "construction_options": {"energy_intensity": {"value": 0.5, "units": "kWh/m^3"}}},
    {"kind": "objective", "name": "objective", "expression": "cost"},
    {"kind": "unit", "name": "waterfacility.tank", "unit_model_class": "Tank",
     "connections": [{"port": "outlet", "to": "waterfacility.plant.inlet"}]},
    {"kind": "costing", "name": "costing", "tariff_source": "tariff.json",
     "dr": {"events_source": "dr_events.json"}},
    {"kind": "plant", "name": "waterfacility"},
    {"kind": "time", "start_date": "2025-01-01", "end_date": "2025-01-30",
     "time_step": "15 min"},
    {"kind": "property_package", "name": "properties",
     "property_class": "SimpleAqueousFlow"}
  ]
}

A quantity with units is data, not code: {"value": 0.5, "units": "kWh/m^3"}, or the string "15 min" for the time step. Units are written as Pyomo prints them, with ** changed to ^.

Assembly order

build_model runs nine stages in a fixed order (STAGES): declare, topology, degradation, surrogates, ramping, logic, state, extensions, costing. Each kind belongs to one stage, and is either mutable (it can be changed on a built model) or not:

Kind

Stage

Mutable

time

declare

no

property_package

declare

no

costing

declare

no

network

topology

no

plant

topology

no

set

topology

no

unit

topology

no

degradation

degradation

no

surrogate

surrogates

yes

ramp

ramping

no

status

logic

no

startup_shutdown

logic

no

dwell

logic

no

bypass

logic

no

startup_delay

logic

no

conditional

logic

no

parallel_group

logic

no

dispatch

state

yes

fix

state

yes

unfix

state

yes

extension

extensions

no

objective

costing

no

Within the logic stage, kinds build in LOGIC_ORDER: status first, because startup, conditional and parallel logic hang off a status binary, and logic between units last. Degradation builds before surrogates, so a surrogate element can replace the wear relations it registers. Costing is processed last because cost_process aggregates whatever is registered when it runs: every power term a unit, a surrogate or an extension registers has to exist by then.

Mutable and immutable kinds

A kind is mutable when changing it on a solved, costed model leaves the costing and the objective valid. Swapping a surrogate replaces a relation in place, and fixing, unfixing or dispatching a variable changes only its value or fixed flag. apply_spec() applies mutable elements to a built model, and refuses an immutable one before changing anything.

Everything else changes the model’s structure, so it is changed in the spec and rebuilt. Swapping a unit, for example, means editing its unit_model_class and calling build_model again. flex-pse never deletes a component from a built model, since anything that captured it would keep a stale reference.

A new element kind is classified the same way: it gets a stage and a mutability flag in KINDS.

Data

Short lists sit inline. A long one, such as a year of prices, a dispatch series or a fixed demand profile, can live beside the spec:

{"kind": "fix", "variable": "plant.product.outlet_state.flow_vol_phase[*,Liq]",
 "value": {"$source": "data/demand.json.gz"}}

A $source also works anywhere in a unit’s construction_options. A $source path is relative to the spec file and names a .json or gzipped .json.gz file. emit_model(data_dir=..., inline_limit=2000) writes every list longer than inline_limit this way, and relative_to= writes paths relative to where the spec will be saved.

A unit that takes several property packages receives them as {"$package": "biogas"} construction options, which name a property_package element.

Fixing variables

A fix element names any variable by its path from the model root and gives its values. An unfix element frees one, such as a parameter a unit fixes by default:

{"kind": "fix", "variable": "plant.battery.charge[0]", "value": 5.0},
{"kind": "fix", "variable": "plant.pretreatment[*].status", "value": 1},
{"kind": "fix", "variable": "plant.intake.flow_in", "value": [120, 120, 95, 80], "units": "m^3/hr"},
{"kind": "unfix", "variable": "plant.ro[*].recovery"}

Paths are Pyomo ComponentUID strings. plant.x is a whole variable, plant.x[3] one point, plant.ro[*].x the variable on every member of ro, and plant.u.flow_vol_phase[*,Liq] every time point of the Liq phase. A path that matches nothing is an error that suggests the closest variable names; a path that matches a Param is an error too, since parameters are set, not fixed.

Values come in four forms: one number for every matched point; a list with one number per time point (or per entry of at); a {time index: value} mapping; or a $source file holding a list or mapping. at restricts the fix to some time indices. units converts the values into each variable’s own units. The time index is the variable’s first index, when that is the TimeBlock’s.

Conflicts are errors. Since file order is irrelevant, there is no “the later fix wins”. Two fix or dispatch elements that set one point to different values, or a fix and an unfix of the same point, stop the build and name the elements involved. Two elements writing the same value are fine.

Bounds and domain. Pyomo itself only logs a warning when a variable is fixed outside its bounds, or a binary to 0.5. The state stage checks every value first, and what happens next is the policy: the element’s on_violation, or the spec’s fix_on_violation when the element sets none.

Policy

Outside bounds

Outside domain (e.g. a binary to 0.5)

Valid points

"error" (default)

Error

Error

Not fixed: nothing in the stage is applied

"warn"

Fixed anyway, with a FlexFixWarning

Error

Fixed

"skip"

Left free, with a FlexFixWarning

Left free, with a FlexFixWarning

Fixed

A bound check passes within an absolute tolerance: the element’s tolerance, or the spec’s fix_tolerance (1e-9). A skipped point is left free for the solver, never clamped to its bound, since a clamped value is one nobody wrote. The state stage is all or nothing: every fix, unfix and dispatch is planned and checked before any of them changes the model. Every warned or skipped point is also logged at WARNING, and listed in the model’s _flex_fix_report (FixReport).

"warn" and "skip" let a run go on with commands that differ from what the spec says. A spec that drives equipment with nobody reading the log should keep the default "error", or escalate the warning so it stops the run: warnings.simplefilter("error", FlexFixWarning).

emit_model writes .fix() and .unfix() calls made in code as these elements. A variable fixed to one value over the whole horizon becomes one number, the same fix on every member of an indexed unit becomes one [*] element, and a fix on some time points uses at. Bounds changed in code (setlb, setub) can’t be written yet and raise a FlexEmitWarning.

Logic, ramps and extensions

Each flexops.logic helper (except relax and unrelax, which are solve strategy) has one element kind: status, startup_shutdown, dwell, bypass, ramp, startup_delay, conditional, parallel_group and degradation. An element names its unit and never sits inside it. The spec checks that every unit named exists and that nothing is set twice on the same unit. Two status rules are checked when the model is built, since only the unit knows them: logic needing an on/off status must find one on the unit (a battery with unit_commitment.status builds its own), and a status element may not target a unit whose allows_status_element is False (Tank, BatteryModel).

An extension element names a user function, as "package.module:function" or an entry point in the flexpse.extensions group, with JSON options. Decorating a function with @flexops.extension makes calling it record the element. Logic helpers called inside an extension record nothing, because rebuilding re-runs the extension. An objective with "expression": "extension" means an extension adds the objective. A spec that uses an extension builds only where its package is installed.

What emit_model checks

emit_model rebuilds the spec it wrote and compares the two models. Anything the spec can’t express yet, such as a constraint added by hand, an objective no extension made, or a surrogate object built without a spec, raises a FlexEmitWarning that names it. Nothing is dropped silently. Things that would change the model if left out (an option with no spec form, indexed members configured differently, an arc no {i} template fits) raise a FlexConfigError.

Surrogates

A SurrogateSpec, carried by a surrogate element, names a predefined surrogate class, one of SurrogateType’s members, and an opaque data mapping in the shape that class defines. The class (flexops.surrogates) validates data and builds the Pyomo relationship. A type not yet implemented raises NotImplementedError when the model is built (quadratic, exponential and neural_network are reserved names, see flexops.surrogates).

arima is implemented by ArimaSurrogate and fitted by ArimaRegressor.

Every surrogate element carries the same envelope, whichever type it is and whether a fit, a live model or a person wrote it:

  • surrogate_type picks the class that defines and validates the rest.

  • config holds everything the surrogate needs besides its fitted values: variables and units, structure, options, and any state. Its shape belongs to the class (see flexops.surrogates).

  • config_version is the version of that type’s config format. A class migrates older versions of its own config when the surrogate is built.

  • parameters maps each fitted value, by the name the built block registers, to {"value": ..., "fixed": true|false}. A value is a number or a list (nested lists for a matrix). fixed covers the whole parameter, defaults to true, and is always written on emit. A free parameter may leave out value to start from the class’s documented initial guess. The names must match the class’s parameters exactly, so a typo is an error rather than a silently fixed coefficient.

  • provenance is free-form fit metadata.

The multilinear class (MultilinearSurrogate) is a constant plus a sum of coefficient * (product of distinct declared inputs). Each entry of terms is a *-separated product of names from input_variables, each at most once. The parameters are intercept, the constant term, plus one per term, named by the term.

{
  "kind": "surrogate",
  "unit": "plant.pump",
  "surrogate_type": "multilinear",
  "config_version": 1,
  "config": {
    "input_variables": {"flow_out": "m^3/hr", "outlet_state.pressure": "Pa"},
    "output_variables": {"power_electrical": "kW"},
    "terms": ["flow_out", "outlet_state.pressure", "flow_out*outlet_state.pressure"]
  },
  "parameters": {
    "intercept": {"value": 5.0, "fixed": true},
    "flow_out": {"value": 0.42, "fixed": true},
    "outlet_state.pressure": {"value": 1.1e-5, "fixed": true},
    "flow_out*outlet_state.pressure": {"value": 2.3e-6, "fixed": true}
  }
}

An arima surrogate puts its order, deterministic term, options and pre-horizon history in config, and names its coefficients intercept (or drift), ar.L1, ma.L1 and exog.<input>. Naming each exogenous coefficient after its input keeps the pair together even if a JSON tool reorders input_variables. Here one coefficient is left free for estimation:

{
  "kind": "surrogate",
  "unit": "plant.ro",
  "relation": "power_electrical_relation",
  "surrogate_type": "arima",
  "config_version": 1,
  "config": {
    "order": [1, 0, 1],
    "deterministic": "intercept",
    "input_variables": {"permeate": "m^3/hr"},
    "output_variables": {"power_electrical": "kW"},
    "history": {
      "start_date": "2025-01-01T00:00:00",
      "time_step_seconds": 3600.0,
      "eta_values": [1.0],
      "eps_values": [0.0]
    }
  },
  "parameters": {
    "intercept": {"value": 2.0, "fixed": true},
    "ar.L1": {"value": 0.5, "fixed": false},
    "ma.L1": {"value": 0.2, "fixed": true},
    "exog.permeate": {"value": 0.8, "fixed": true}
  }
}

A constant_intensity surrogate swaps no relation. It sets the unit’s own energy_intensity, its one parameter:

{
  "kind": "surrogate",
  "unit": "plant.pump",
  "surrogate_type": "constant_intensity",
  "parameters": {"energy_intensity": {"value": 0.9, "fixed": true}}
}

A unit can carry several surrogates, one element per relation. An RO skid can have one on split_definition and another on power_electrical_relation. Building, applying or emitting a surrogate logs which of its parameters are free, at INFO when any are and at DEBUG when all are fixed.

The declared units are the basis the relationship was fitted in. Each input converts from the model’s units into its declared ones before the coefficient multiplies it, and the result converts into the target’s units. A dimensionally incompatible declaration raises a FlexConfigError instead of silently rescaling.

Only relationships a unit registered with register_relation() can be swapped: every constant-intensity energy relation, an RO skid’s split_definition, a tank’s level_definition. Conservation constraints are never registered, so they can never be swapped. iter_swapped_relations() reports which registered relations have been swapped.

Versioning

Every spec carries a mandatory schema_version, a semantic version string (SCHEMA_VERSION). On load, a missing, malformed or too-new version raises a FlexConfigError, and an older one steps through MIGRATIONS before validation. Pydantic models in flexcore.config.spec are the schema authority and reject undocumented keys.

Schema 0.2.0 replaced each surrogate element’s data with config and parameters. A 0.1.1 file still loads: every coefficient the old build created becomes a fixed parameter at the value the old build gave it, so the migrated spec builds the same model. A saved standalone surrogate spec can be upgraded with migrate_surrogate_spec(). Changes to one surrogate type’s config don’t change the schema version; that type bumps its own config_version instead. Their exported JSON Schema is checked in under src/flexcore/config/schemas/, so schema changes show up in review and other tools can validate against it. Changing the default fix policy is a breaking change and needs a new version. Version 0.1.1 renames the BatteryModel capacity option and Var to energy_capacity; a 0.1.0 spec is rewritten on load, except for extension functions, which are user code.

The FlexParameterize and FlexOps seam

The spec is also the contract between FlexParameterize and FlexOps. FlexParameterize changes a live FlexOps model in place, and emit_model() writes that model out as a spec that rebuilds it.

Field reference

Field

Type

Default

Description

schema_version

str

required

Semantic schema version of this spec, an X.Y.Z string; mandatory, no default.

name

str

required

Name of the Pyomo ConcreteModel.

solver

str | None

None

Optional solver name; None lets the facade pick.

elements

list

required

Every element of the flowsheet; order is irrelevant.

fix_on_violation

Literal

‘error’

Default bounds/domain policy for every fix element that doesn’t set its own.

fix_tolerance

float

1e-09

Default absolute tolerance for the fix bounds check.

Field

Type

Default

Description

start_date

str

required

Inclusive ISO-8601 start of the horizon.

end_date

str

required

Exclusive ISO-8601 end of the horizon.

time_step

str

required

Time-step as a units-carrying expression string, e.g. ‘15 min’; parsed at build time.

kind

Literal

required

Field

Type

Default

Description

property_class

str

required

Name of a flexops property-package class, e.g. ‘SimpleAqueousFlow’ or ‘SimpleGasFlow’.

options

dict

PydanticUndefined

Keyword options passed to the property-package constructor, e.g. {‘has_pressure’: true}.

kind

Literal

required

name

str

required

Name of the package on the model.

Field

Type

Default

Description

kind

Literal

required

name

str

required

Name of the costing block on the model.

tariff_source

str | list[str] | dict[str, str] | None

None

Where the EECO tariff comes from: one file or tag, a list of them to merge, or a mapping of EECO utility (‘electric’/’gas’) to file to merge and also assign each file to a utility. Omit to price every carrier from energy_prices instead.

energy_prices

dict[str, flexcore.config.spec.SourcedPrice] | None

None

Optional native prices keyed by carrier or fuel name (‘electrical’, or a fuel such as ‘natural_gas’). A carrier priced here is billed at that price instead of through the tariff, so a run with every carrier priced needs no tariff at all. Each price is flat over the horizon or given per time point.

export_prices

dict[str, flexcore.config.spec.SourcedPrice] | None

None

Optional prices paid for exports, keyed like energy_prices (‘electrical’ or a fuel name). Each key needs a matching energy_prices entry and must not exceed it at any time point. A carrier left out credits exports at its import price.

decomposition_type

str | None

None

Optional EECO decomposition of net electrical power and fuel usage into imports and exports on the tariff path (e.g. ‘linear’), so the tariff’s export charges apply. Passed straight to EECO.

currency

str

‘USD’

Currency basis to use when no tariff is given; a tariff’s own currency basis always wins.

dr

flexcore.config.schema.DRConfig | None

None

Optional demand-response container (containers-only in v0).

consumption_estimate

dict[typing.Literal[‘electric’, ‘gas’], float] | None

None

Estimated total consumption over the horizon, keyed by EECO utility (‘electric’/’gas’; kWh / m^3). EECO needs it to price any tier other than a flat top tier.

fixed_operating_cost

float

0.0

Fixed operating cost over the horizon, in the currency basis in force (a tariff’s own, else ‘currency’): non-tariff costs such as maintenance, labor, and chemicals. Distinct from the tariff’s own fixed charge (which EECO includes in the electricity cost).

prorate_monthly_charges

bool

True

Prorate a tariff’s monthly-assessed demand charge and fixed (customer) charge to the horizon length when the horizon is shorter than the calendar month it starts in. False bills the full monthly charges.

lifetime_years

float

20.0

Plant lifetime in years (> 0), used with the effective rate to form the capital recovery factor that annualizes capital cost.

discount_rate

float

0.08

Annual discount rate (fraction, e.g. 0.08 = 8%). Used alone as the effective rate when interest_rate is unset; otherwise it deflates interest_rate into a real effective rate. An effective rate of 0 falls back to straight-line 1/lifetime.

interest_rate

float | None

None

Optional annual cost of capital (fraction, e.g. 0.06). When given, the capital recovery factor uses the effective rate (1 + interest_rate) / (1 + discount_rate) - 1. Omit to use discount_rate alone.

Field

Type

Default

Description

kind

Literal

required

name

str

required

Dotted path of the network on the model.

Field

Type

Default

Description

kind

Literal

required

name

str

required

Dotted path of the plant on the model.

Field

Type

Default

Description

kind

Literal

required

name

str

required

Dotted path of the set on the model.

values

list

required

The set’s members, in order; non-empty and unique.

Field

Type

Default

Description

kind

Literal

required

name

str

required

Dotted path of the unit on the model.

unit_model_class

str

required

Name of the flexops unit-model class to construct.

construction_options

dict

PydanticUndefined

Keyword options passed to the unit-model constructor. A value {‘$package’: name} passes the named property_package element.

property_package

str | None

‘auto’

Name of a property_package element. ‘auto’ means the model’s only one (an error if it has several); null gives the unit none.

costing_package

str | None

‘auto’

Name of a costing element. ‘auto’ means the model’s only one; null leaves the unit uncosted.

index

str | None

None

Name of a set element; the unit is built once per member.

connections

list

PydanticUndefined

Arcs leaving this unit. Each arc is written once, on its source unit.

io_variables

list

PydanticUndefined

Declared process input/output variables of the unit.

unit_commitment

flexcore.config.schema.UnitCommitmentConfig | None

None

Per-unit unit-commitment configuration. Unset (null) leaves the unit model’s own default in force.

Field

Type

Default

Description

port

str

required

Port on the owning unit, e.g. ‘outlet’.

to

str

required

Destination as ‘<unit element name>.<port path>’; may contain ‘{i}’ for an indexed connection.

name

str | None

None

Name of the arc on the model; omitted: derived from the endpoints.

doc

str | None

None

Optional arc description.

index

str | None

None

Name of a set element to index the arc over; omitted: the owning unit’s index, if it has one.

directed

bool

True

False builds an undirected arc between the two ports.

Field

Type

Default

Description

surrogate_type

SurrogateType

required

Which predefined surrogate class this relationship is. The class (flexops.surrogates) validates config and parameters and builds the relationship; a class not yet implemented raises NotImplementedError when the model is built, not when the config is validated.

config_version

int

1

Version of this surrogate type’s config format. Each surrogate class migrates older versions of its own config when it is built. Always written on emit.

config

dict

PydanticUndefined

Everything the surrogate needs besides its parameters (variables and units, structure, options, state such as an ARIMA history), in the shape surrogate_type’s class defines and validates. Opaque to the schema; see the flexops.surrogates reference page for each class’s config.

parameters

dict

PydanticUndefined

The surrogate’s fitted values, keyed by the names its class registers (for example ‘intercept’, ‘ar.L1’, ‘exog.feed’). The names must match the class’s parameters exactly.

provenance

dict

PydanticUndefined

Free-form fit metadata (metrics, data window, versions).

kind

Literal

required

unit

str

required

Name of the unit element it applies to.

relation

str

‘power_electrical_relation’

Name of the unit’s relation to replace.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

unit

str

required

Name of the unit element, or ‘name[i]’ for one member of an indexed unit.

variable

str

required

Path of the time-indexed variable relative to the unit, e.g. ‘flow_in’.

ramp_up

float | None

None

Largest increase per step, in units.

ramp_down

float | None

None

Largest decrease per step, in units.

units

str

required

Units of ramp_up and ramp_down, e.g. ‘kW/h’.

window

int

1

Number of steps the ramp is measured across.

component_name

str | None

None

Stem of the built component names; omitted: ‘<variable>_ramp’.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

unit

str

required

Name of the unit element, or ‘name[i]’ for one member of an indexed unit.

variable

str

required

Path of the time-indexed variable relative to the unit, e.g. ‘flow_in’.

min_output

float | flexcore.config.spec.Quantity

required

Output when on, lower limit: a number or a quantity.

max_output

float | flexcore.config.spec.Quantity

required

Output when on, upper limit: a number or a quantity.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

unit

str

required

Name of the unit element, or ‘name[i]’ for one member of an indexed unit.

min_up

int

1

Minimum steps on after a startup.

min_down

int

1

Minimum steps off after a shutdown.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

unit

str

required

Name of the unit element, or ‘name[i]’ for one member of an indexed unit.

variable

str

required

Path of the time-indexed variable relative to the unit, e.g. ‘flow_in’.

k

int

required

Block length in steps.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

unit

str

required

Name of the unit element, or ‘name[i]’ for one member of an indexed unit.

variable

str

required

Path of the time-indexed variable relative to the unit, e.g. ‘flow_in’.

max

float | flexcore.config.spec.Quantity

required

Upper limit on the bypassed flow: a number or a quantity.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

unit

str

required

Name of the unit element, or ‘name[i]’ for one member of an indexed unit.

upstream

str

required

Name of the unit element that must run first.

k

int

required

Steps the unit lags behind the upstream unit.

initially_on

bool

True

Whether the upstream unit counts as already warmed up at the start of the horizon.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

unit

str

required

Name of the unit element, or ‘name[i]’ for one member of an indexed unit.

implies

str

required

Name of the unit element whose state follows.

state

Literal

‘on’

State of the implied unit while this one is on.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

units

list

required

Unit element names, in priority order.

variables

list

PydanticUndefined

Variables ordered the same way across the group.

order_status

bool

True

Whether to order the units’ status binaries.

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

unit

str

required

Name of the unit element it applies to.

variable

str

required

Name of the time-indexed variable on the unit.

values

list[float] | dict[str, float] | flexcore.config.spec.SourceRef

required

One value per time point as a list, a mapping of time index to value, or a $source reference to a file holding either.

fix

bool

True

Whether to fix the variable to the values (removing its degrees of freedom).

name

str | None

None

Optional label; not used to build anything.

Field

Type

Default

Description

kind

Literal

required

name

str | None

None

Optional id, used in error messages.

variable

str

required

Pyomo ComponentUID path from the model root, e.g. ‘plant.pump.flow_in’, ‘plant.pump.flow_in[3]’, ‘plant.ro[*].status’ or ‘plant.u.flow_vol_phase[,Liq]’. A star () matches every index in that position.

value

float | list[float] | dict[str, float] | flexcore.config.spec.SourceRef

required

One number for every matched point; a list with one number per time point (or per entry of at); a {time index: value} mapping; or a $source file holding either.

units

str | None

None

Units of value; omitted means each variable’s own units.

at

list[int] | None

None

Only fix these time indices; omitted means every matched point.

on_violation

Optional

None

What to do when a value is outside the variable’s bounds or domain: ‘error’ raises and fixes nothing; ‘warn’ fixes out-of-bounds points anyway and warns; ‘skip’ leaves violating points unfixed, fixes the rest, and warns. Omitted means the spec’s fix_on_violation.

tolerance

float | None

None

Absolute tolerance for the bounds check, in the variable’s units. Omitted means the spec’s fix_tolerance.

Field

Type

Default

Description

kind

Literal

required

name

str | None

None

Optional id, used in error messages.

variable

str

required

ComponentUID path from the model root, as for fix.

Field

Type

Default

Description

kind

Literal

required

name

str

required

Name of this call; unique among extensions.

entry_point

str

required

‘package.module:function’, or the name of an entry point in the ‘flexpse.extensions’ group.

options

dict

PydanticUndefined

Keyword options passed to the function.

Field

Type

Default

Description

kind

Literal

required

name

str

‘objective’

Name on the model.

expression

Literal

‘cost’

‘cost’ optimizes a costing element’s cost; ‘extension’ means an extension adds the objective.

costing_package

str

‘auto’

Name of the costing element whose cost is optimized; ‘auto’ means the model’s only one.

sense

Literal

‘minimize’

Direction of optimization.

Field

Type

Default

Description

surrogate_type

SurrogateType

required

Which predefined surrogate class this relationship is. The class (flexops.surrogates) validates config and parameters and builds the relationship; a class not yet implemented raises NotImplementedError when the model is built, not when the config is validated.

config_version

int

1

Version of this surrogate type’s config format. Each surrogate class migrates older versions of its own config when it is built. Always written on emit.

config

dict

PydanticUndefined

Everything the surrogate needs besides its parameters (variables and units, structure, options, state such as an ARIMA history), in the shape surrogate_type’s class defines and validates. Opaque to the schema; see the flexops.surrogates reference page for each class’s config.

parameters

dict

PydanticUndefined

The surrogate’s fitted values, keyed by the names its class registers (for example ‘intercept’, ‘ar.L1’, ‘exog.feed’). The names must match the class’s parameters exactly.

provenance

dict

PydanticUndefined

Free-form fit metadata (metrics, data window, versions).