BatteryModel

class flexops.unit_models.storage.battery.BatteryModel(*args, **kwds)

Bases: ProcessBlock

Parameters:
  • rule (function) – A rule function or None. Default rule calls build().

  • concrete (bool) – If True, make this a toplevel model. Default - False.

  • ctype (class) –

    Pyomo ctype of the block. Default - pyomo.environ.Block

    Config args

    dynamic

    Indicates whether this model will be dynamic or not, default = useDefault. Valid values: { useDefault - get flag from parent (default = False), True - set as a dynamic model, False - set as a steady-state model.}

    has_holdup

    Indicates whether holdup terms should be constructed or not. Must be True if dynamic = True, default - False. Valid values: { useDefault - get flag from parent (default = False), True - construct holdup terms, False - do not construct holdup terms}

    property_package

    Property (parameter) block carrying flow between units; None for units that need no fluid properties.

    flexops_config

    Optional already-validated UnitConfig for this unit (never a raw dict).

    unit_commitment

    Per-unit unit-commitment sub-config.

    external_dispatch

    Optional external (DERMS) dispatch source consumed by set_external_dispatch.

    relaxation

    Discrete-structure relaxation policy.

    allow_pass_through

    Whether add_bypass_constraints() builds inlet-to-outlet pass-through equalities for this unit’s non-excluded state variables. SISOBlock (and its subclasses Pump/Tank) override the base default to True so the flow-topology units are well-posed out of the box; the base OpsBlock default stays False.

    costing_package

    Optional FlexCosting block this unit associates with: register_power forwards the unit’s power draw to it. None for standalone units; the forwarding is strictly conditional.

    energy_capacity

    Initial battery energy capacity, kWh – the fixed design Var value at construction. Required.

    power_charge_max

    Maximum charging power, kW. None (default) falls back to a 1C rate (the whole energy capacity in one hour) – with unit_commitment.status enabled, its semicontinuous link needs a finite bound; the fallback applies either way so a bare battery is never unbounded. Give it and power_discharge_max together or not at all.

    power_discharge_max

    Maximum discharging power, kW. Same rule as power_charge_max, including the 1C fallback.

    eta_charge

    Charging efficiency, a fraction in (0, 1].

    eta_discharge

    Discharging efficiency, a fraction in (0, 1].

    soc_min

    Minimum state of charge, a fraction of energy capacity in [0, 1].

    soc_max

    Maximum state of charge, a fraction of energy capacity in [0, 1].

    initial_soc

    Initial state of charge, a fraction of energy capacity in [0, 1], before step 0’s flows; sets the charge_init Var (rolling-horizon state).

    fix_initial_state

    Fix the charge_init Var and register it as rolling-horizon initial state; False leaves it free, so the solve chooses the starting charge.

    cyclic

    Require the final charge to be at least the starting charge.

    soh

    State of health, a fraction of nameplate energy capacity still available due to degradation; fixes soh at construction. Default 0.85 represents a mid-life battery.

    charge_leakage_rate

    Self-discharge (charge leakage) rate: fraction of stored charge lost per day, fixing charge_leakage_rate at construction. Default 0.0005/day (0.05%/day).

  • initialize (dict) – ProcessBlockData config for individual elements. Keys are BlockData indexes and values are dictionaries with config arguments as keys.

  • idx_map (function) – Function to take the index of a BlockData element and return the index in the initialize dict from which to read arguments. This can be provided to override the default behavior of matching the BlockData index exactly to the index in initialize.

Returns:

(BatteryModel) New instance

Variables

Name

Index

Units

Role

Description

power_charge

time

kW

input

Charging power draw (dispatch input).

power_discharge

time

kW

input

Discharging power output (dispatch input).

power_electrical

time

kW

output

Electrical draw of the unit

charge

time

kWh

output

Stored energy content.

Constraints

Name

Description

power_charge_limit

power_charge[t] <= power_capacity.

power_discharge_limit

power_discharge[t] <= power_capacity.

net_electrical

power_electrical == power_charge - power_discharge (discharge is a negative/export draw; v0 is behind-the-meter).

charge_balance

Charge holdup (backward difference): charge[t] == charge[t-1]*(1 - charge_leakage_rate*dt) + dt*(eta_charge*power_charge[t] - power_discharge[t]/eta_discharge); t=0 references charge_init in place of charge[-1], so power_charge[0]/power_discharge[0] are energy-conserving too (a separate, unconstrained-at-t=0 initial condition would let power_charge[0]/power_discharge[0] move for free, manufacturing energy from nothing).

soc_lower_limit

charge[t] >= soc_min * energy_capacity.

soc_upper_limit

charge[t] <= soc_max * energy_capacity.

charge_init_lower_limit

charge_init >= soc_min * energy_capacity.

charge_init_upper_limit

charge_init <= soc_max * energy_capacity.

charge_init_soh_limit

charge_init <= soh * energy_capacity.

soh_capacity_limit

State-of-health limit: charge[t] <= soh * energy_capacity. Independent of soc_max – soh models capacity fade from degradation, while soc_max is an operational headroom fraction of nameplate energy capacity.

Degrees of Freedom

Name

Units

Description

power_charge

kW

Charging power draw (dispatch input).

power_discharge

kW

Discharging power output (dispatch input).