Pass through, bypass, and the arc layer¶
The words pass through and bypass name three distinct things in flex-pse. All three concern flow moving between an inlet and an outlet, which makes them easy to confuse. This page fixes the vocabulary.
Pass through, copying a property inside a unit (available now)¶
A single unit model must be well posed on its own. With its inlet
states fixed, its outlet states must be fully determined (degrees of
freedom equal 0). For every state variable a unit does not otherwise
govern, the outlet simply equals the inlet.
OpsBlockData.add_pass_through_constraints(inlet, outlet, *, exclude_vars=()) builds exactly those equalities, outlet_var[idx] == inlet_var[idx] over each variable’s full index set, and skips any
variable that’s already fully fixed (an inlet held at a known pressure,
say, where the constraint would be redundant).
The allow_pass_through config slot gates this behavior. SISOBlock (and
its subclasses Pump/Tank) override the base default to True, so the
flow topology is well posed out of the box. The base OpsBlock default is
False. Each generated constraint takes the name pass_through_{name}_eq,
for example pass_through_flow_vol_phase_eq.
Subclasses that genuinely govern a variable exclude it and wire their own relationship instead.
Pump(hydraulic relation) excludespressure. A pump raises pressure between its ports rather than passing it through.Tankexcludes the flow basis variable. Its holdup difference equation governs flow instead.
Pass through is not a physical stream. It’s bookkeeping that copies properties the unit doesn’t otherwise govern, just enough to close the unit.
Bypass, a stream that diverts flow¶
A bypass is a real physical stream, a fraction of a flow routed
around a unit’s energy relation instead of through it.
flexops.logic.bypass.add_bypass(unit, flow_var, bypass_max) attaches
three things.
bypass_flow[t], aVarbounded[0, bypass_max], the diverted flow.treated_flow[t], the quantity the unit’s energy relation should consume in place of the raw flow.treated_flow_eq[t], which readstreated_flow[t] == flow_var[t] - bypass_flow[t].
This changes what the unit actually processes, so it’s a genuinely
different kind of behavior than pass through. add_bypass only introduces
the treated_flow quantity. Rewiring Ports/Arcs to physically route a
stream around a whole unit block is a flowsheet level concern, described
next.
The arc and topology layer¶
Neither of the above connects one unit to another. Connectivity at the
flowsheet level, arcs between unit ports, network conservation, and any
routing across a plant, lives one level up, in PlantBlock (a collection
of units) and NetworkBlock (a collection of plants). See
flexops.core for how they compose units and plants
over standard IDAES/Pyomo Arcs. A bypass at the flowsheet level (routing
a stream around a whole unit block by rewiring arcs, rather than the
treated_flow substitution described above) belongs there.
Summary¶
Term |
Scope |
Builds |
|---|---|---|
Pass through |
Within one unit |
|
Bypass stream |
Around one unit’s energy relation |
|
Arc layer |
Between units (flowsheet) |
Ports/Arcs, conservation |
Reserve bypass for the stream that diverts flow. Use pass through for copying a property inside one unit.