Run a design study¶
A design study sizes equipment once, for a plant that then operates across several representative months and years. You write one base flowsheet and describe how it varies.
Write the study file¶
{
"schema_version": "0.1.0",
"name": "pump_battery_solar",
"base": "base_flowsheet.json",
"years": [
{"year": 2026, "represents": 5},
{"year": 2031, "represents": 5}
],
"months": [
{"month": 1, "weight": 6},
{"month": 7, "weight": 6}
],
"changes": [
{"element": "pv", "months": [1], "values": {"construction_options": {"capacity_factor": {"$source": "pv_jan.json"}}}},
{"element": "pv", "months": [7], "values": {"construction_options": {"capacity_factor": {"$source": "pv_jul.json"}}}},
{"element": "costing", "years": [2031], "values": {"energy_prices": {"electrical": {"value": 0.12}}}}
],
"capacities": [
{"name": "battery_energy", "variable": "battery.energy_capacity", "capital_cost": 300.0, "lifetime_years": 15, "upper": 1500.0},
{"name": "battery_power", "variable": "battery.power_capacity", "capital_cost": 200.0, "lifetime_years": 15, "upper": 1500.0},
{"name": "solar", "variable": "pv.capacity", "capital_cost": 1200.0, "lifetime_years": 25, "upper": 1500.0}
]
}
Then build, solve and report:
from flexcore.config.design import load_design_spec
from flexcore.solvers import get_solver
from flexdesign import build_design_model, design_results
m = build_design_model(load_design_spec("study.json"))
get_solver(m).solve(m)
print(design_results(m).summary())
Choose years and months¶
yearssets how many years are modeled.representssays how many calendar years each one stands in for, and the study length is the sum. Modeled years must be consecutive under it: 2026 representing 5 must be followed by 2031.monthssets how many representative months each year runs.weightsays how many months of the year each one stands in for, and weights must sum to 12.
The model holds one horizon per year and month, so its size is the product of the two. Start small: a 5-year, 4-month hourly study is 20 months of constraints.
To try a study quickly, set "days": 1 on a month. Only the first days are modeled, and that bill is scaled up to the full month. Every series for that month must then have one value per modeled time step. A prorated month doesn’t capture a whole month’s peak, so use whole months for final sizes.
Cap total capital spending¶
Set "capex_budget" on the study to limit the sum of the decisions’ overnight capital costs (capital_cost times size). The budget is a one-time spend in the model currency and isn’t prorated by lifetime. Use it when operating revenue could otherwise make sizes grow to their upper bounds. Without it, only each decision’s upper bound limits size.
"capex_budget": 250000.0
Report NPV and IRR¶
investment_metrics compares the design against a baseline annual operating cost, keyed by the same modeled years. To get one, copy the study, set every capacity’s upper to 0, solve it, and read its operating costs. A dict from another source, such as utility bills, also works.
from flexdesign import investment_metrics
baseline = design_results(baseline_m).annual_operating_cost_by_year
metrics = investment_metrics(design_results(m), baseline, horizon_years=20)
print(metrics.summary())
horizon_years defaults to the study length. Years past the study repeat the last modeled year. Assets that wear out inside the horizon are bought again, and any life remaining at the end is credited at straight-line value. See How design studies annualize cost.
Vary parameters by month and year¶
Everything that varies goes through changes. An entry names a base element and the values to deep-merge into it, and selects where it applies.
To vary |
Selector |
Example |
|---|---|---|
By month, every year |
|
Solar forecast, seasonal prices |
By year, every month |
|
Price escalation, battery |
One month of one year |
|
A forecast that changes both ways |
Everywhere |
Neither |
A study-wide replacement of a base value |
Lists are replaced whole, and later entries win when two match the same field.
To change a
fixelement, give it anamein the base spec.Dates come from the year and month, so changes can’t edit
time.Values are absolute, so a series that varies by both month and year needs a change for each combination.
Prepare solar forecasts¶
A forecast is a capacity factor series: output per kW of nameplate, from 0 to 1, with one value per time step. It has to be normalized because output is capacity_factor[t] * capacity, which is what lets it scale as the size changes. A forecast for a 1 kW system is already in this form. Otherwise, divide by the system’s rated kW.
Warning
Forecast files are matched by position, starting at the first time step of the month, and only their length is checked. January and July both have 744 hours, so swapping those files builds and solves with wrong results.
By default solar output cannot be curtailed, so all generation has to go somewhere. Limiting exports to zero with GridConnection can then make a model infeasible. Set "curtailable": true on the GenericRenewables unit to let the optimizer spill the excess.
Prepare the base flowsheet¶
Free the starting state of storage. Set
"fix_initial_state": falseon each battery and tank, since a study rejects any fixed initial state. Also set"cyclic": true, which requires each month to end at least as full as it started, so no month can drain free stored energy.Set constructor limits at or above sizing bounds. A decision’s
uppercan’t exceed its Var’s own bound, andbattery.power_capacityis bounded by the larger ofpower_charge_maxandpower_discharge_max.Give every decision an
upper. With net metering, an unbounded capacity can make the problem unbounded. If a report flags a size as at its upper bound, the bound is probably driving the answer.Set an export price if exports aren’t credited at the import price. Otherwise surplus solar earns the full import price.
Work with the merged model¶
The merged model holds several time blocks, so helpers that look for a single one raise an error once horizons are merged:
set_external_dispatch,set_dispatch,add_stream_portsanddeclare_powerlogic helpers
apply_specwithdispatchelementsemit_modelandmodel_differencesat the merged root
Apply these per horizon through changes, or to the standalone models from build_horizons. Fit parameters with flexparameterize before merging, since unit names gain a prefix afterward. The saved form of a merged model is its study file.