Steam boilers

Boiler is a linear steam boiler for scheduling. It comes in two types, chosen with boiler_type:

  • BoilerType.FIRED burns one or more fuels.

  • BoilerType.HEAT_RECOVERY (a heat recovery steam generator, HRSG) raises steam from a hot gas stream, such as a Combustor’s flue gas. Duct firing is optional.

Both types share the same thermal lag, feedwater inlet, steam outlet, on/off status, and auxiliary power draw. Every coefficient in the model is a fixed, regressable parameter or a swappable relation. Each one maps onto an output of a detailed first-principles boiler model, so a high-fidelity simulation can be reduced to boiler parameters directly (see the mapping table below).

Ports

Port

Stream

Property package

inlet_<fuel>

one per name in fuel_inlet_names

fuel_property_package (gas)

inlet_hot_gas

hot gas, heat recovery only

hot_gas_property_package (gas)

outlet_gas

cooled gas, heat recovery only

hot_gas_property_package (gas)

inlet_feedwater

feedwater

feedwater_property_package (liquid)

outlet_steam

steam

steam_property_package (gas)

Fuels can enter through inlet ports, for example biogas from a Digestor. They can also come from utilities (utility_fuel_source), for example natural gas billed through the tariff. A boiler can use both kinds at once. Every fuel needs an entry in heating_values. A fired boiler needs at least one fuel. A fired boiler has no flue gas outlet, because combustion air and flue gas are not modeled.

Equations

Write \(Q_t\) for heat_output[t] (kW of steam heat), \(f_{i,t}\) for each fuel’s volumetric flow, \(g_t\) for flow_hot_gas[t], and \(s_t\) for status[t]. \(s_t = 1\) when unit commitment status is off.

Heat input. Recovered heat is its own relation, so a detailed recovery curve can replace it without touching the firing term:

\[\dot{Q}^{rec}_t = c_{gas}\, g_t\]
\[\dot{Q}^{abs}_t = \eta \sum_i \mathrm{HV}_i\, f_{i,t} + \dot{Q}^{rec}_t - \dot{Q}^{loss}\, s_t, \qquad \sum_i \mathrm{HV}_i\, f_{i,t} \le \dot{Q}^{fire}_{max}\]

Here \(c_{gas}\) is gas_heat_content, \(\eta\) is efficiency, \(\dot{Q}^{loss}\) is no_load_loss, and \(\dot{Q}^{fire}_{max}\) is max_firing_rate, the burner capacity. Without fuel the firing term drops out, and without hot gas the recovered term drops out.

Thermal lag. The water and metal in the pressurized parts store heat in proportion to load. The boiler therefore follows its firing with a first-order lag of time constant \(\tau\) (time_constant). Following the codebase’s backward-difference convention:

\[\tau\,(Q_t - Q_{t-1}) = \Delta t\,\big(\dot{Q}^{abs}_t - Q_t - \dot{Q}^{dis}_t\big), \qquad Q_{-1} = Q_{init}\]

Raising load by \(\Delta Q\) in one step costs an extra \(\tau\,\Delta Q / \Delta t\) of absorbed heat, which means overfiring. When \(\Delta t \gg \tau\) the lag fades away and the boiler sits at steady state. With \(\tau = 0\) the boiler is static. The term \(\dot{Q}^{dis}_t \ge 0\) (heat_dissipated) is heat vented or lost. Without it a fast ramp-down or shutdown would be infeasible, because the stored heat has to go somewhere and firing can’t go negative. An unfired HRSG also uses it to dump recovered heat while it’s off. The term has no price, since it only wastes heat that was already paid for. initial_heat_output is a fixed scalar Var registered as the rolling-horizon initial state.

Steam and feedwater.

\[e_{steam}\, \dot{V}^{steam}_t = Q_t, \qquad \dot{V}^{fw}_t = r_{\rho}\, \dot{V}^{steam}_t\]

Here \(e_{steam}\) is steam_heat_content, the heat carried per m³ of outlet steam relative to the feedwater (Δh·ρ). \(r_{\rho}\) is steam_to_water_density_ratio, which conserves mass across the two volumetric streams. Outlet pressure equals steam_pressure (steam_pressure_relation) and outlet temperature equals steam_temperature. In heat recovery mode, cooled gas flow equals hot gas flow, pressure passes through, and the outlet temperature equals stack_temperature.

Power. Steam heat is a thermal export, power_thermal = -heat_output, registered at the steam temperature. The auxiliary electrical draw for fans and controls is power_electrical = energy_intensity * flow_out, with energy_intensity = aux_energy_intensity. With unit commitment status on, min_heat_output * status <= heat_output <= max_heat_output * status. Startup costs and delays come from the usual unit commitment helpers (add_startup_shutdown, add_startup_delay), applied to the built unit.

The swappable relations are heat_absorbed_relation, heat_recovered_relation (heat recovery only), steam_flow_relation, steam_pressure_relation, and power_electrical_relation. A config file’s surrogate swaps power_electrical_relation, as for every unit. The other relations are swapped at runtime with swap_relation. The energy balance, feedwater balance, and sign constraints are never swappable.

From a detailed model to boiler parameters

The mapping below follows the experiments of Taler et al. (2019), who built a distributed-parameter model of a 910 MW supercritical once-through boiler. That model solves mass, momentum, and energy balances along every heating surface and is validated against the manufacturer’s steady-state data.

Boiler item

Detailed-model experiment or output

efficiency, no_load_loss, or a surrogate on heat_absorbed_relation

Steady states along the sliding-pressure curve (e.g. 40, 80, 87.5, and 100 % load): heat absorbed by the working fluid vs. fuel heat input

gas_heat_content, or a surrogate on heat_recovered_relation (inputs: gas flow and inlet temperature)

HRSG steady states: heat absorbed vs. hot gas flow and inlet temperature

stack_temperature

Gas temperature leaving the last heat exchanger

max_firing_rate

Burner or mill capacity

time_constant

A fuel or gas step test, such as the paper’s +7.5 % load step from 80 %. Use the time to reach about 63 % of the steam heat output change, less the fuel transport delay

steam_heat_content, steam_to_water_density_ratio

Outlet Δh·ρ and ρ_steam/ρ_feedwater, or a surrogate on steam_flow_relation fitted to outlet flow vs. heat output

surrogate on steam_pressure_relation (input: heat_output)

The sliding-pressure curve, live steam pressure vs. load

min_heat_output, max_heat_output

Minimum stable load and rated output

aux_energy_intensity

Auxiliary electrical consumption per unit of steam

startup helpers

Cold, warm, and hot start-up simulations: fuel used and time to stable load

Set fitted scalars with update_parameters. Attach fitted curves with swap_relation and a MultilinearSurrogate.

What was left out, and why

The detailed model resolves many transients that are much faster than a scheduling step. They are dropped to keep the model small:

  • Fuel transport delay (about 5 s from mill to burner) and the mill load ramp (about 40–50 s per load step).

  • Pressure-sliding reserve. Dropping live steam pressure by 10 bar releases stored steam, about 22 kg/s for about 40 s in the paper’s boiler. Once the pressure stops falling, that steam has to be paid back by overfiring. The released energy is about 2 GJ, roughly one second of the boiler’s 1838 MW thermal output. At 15-minute or hourly steps it can’t shift energy, so it matters only for sub-minute reserve products, which call for a different formulation.

  • Air heater temperature oscillations and the evaporator switch from circulation to once-through flow.

The thermal lag is the one transient that is kept. It is worth keeping whenever \(\tau\) is not small compared with \(\Delta t\), for example minutes against a 15-minute step. Otherwise set \(\tau = 0\).

Operating pressure

The model has no pressure ceiling. Every quantity that depends on pressure is a parameter, and the property packages only require pressure and temperature to be positive. Two example parameter sets:

10 bar saturated (default)

1500 psig (≈103 bar), 540 °C, 230 °C feed

steam_pressure

10 bar

103 bar

steam_temperature

453 K

813 K

steam_heat_content

3.4 kWh/m³

≈20 kWh/m³

steam_to_water_density_ratio

0.0054

≈0.036

The paper’s 285 bar supercritical unit fits the same way, since “vapor” is only the label of the outlet’s single phase. Under sliding-pressure operation, steam density changes strongly with load, so a single steam_heat_content misstates part-load volumetric flow. In that case, swap a detailed-model flow curve onto steam_flow_relation.

Example: heat recovery behind a combustor

import pyomo.environ as pyo
import flexops as fo

m.chp = fo.Combustor(property_package=m.gas, inlet_names=("fuel",))
m.hrsg = fo.Boiler(
    boiler_type=fo.BoilerType.HEAT_RECOVERY,
    hot_gas_property_package=m.gas,
    feedwater_property_package=m.water,
    steam_property_package=m.steam,
    utility_fuel_source="natural_gas",  # duct firing
    heating_values={"natural_gas": 10.5 * pyo.units.kWh / pyo.units.m**3},
)
m.flue = pyo.network.Arc(source=m.chp.outlet, destination=m.hrsg.inlet_hot_gas)

Reference

J. Taler, W. Zima, P. Ocłoń, S. Grądziel, D. Taler, A. Cebula, M. Jaremkiewicz, A. Korzeń, P. Cisek, K. Kaczmarski, and K. Majewski, “Mathematical model of a supercritical power boiler for simulating rapid changes in boiler thermal loading,” Energy 175 (2019) 580–592. doi:10.1016/j.energy.2019.03.085