flexops.unit_models ==================== Unit models are organized by inlet and outlet topology first (the ``base`` sub-package), then specialized physically. The topology base owns port construction and the per-stream mass balance, and a physical subclass adds the relationship between flow and energy plus any bounds. ``Pump`` and ``Tank`` subclass ``SISOBlock``, which has a single inlet and a single outlet. A ``Tank`` also disables the on/off logic layer, since a tank has no unit commitment status. Every unit defaults to a **constant energy intensity** and builds it as the Constraint ``power_electrical_relation`` (``power_thermal_relation`` for a heat duty). That name is the swap contract. FlexParameterize upgrades a unit's relationship by deactivating exactly that Constraint and attaching a fitted replacement, and it reuses the same registered IO variables, so there is no separate regression unit class. **Picking a base when adding a new unit model**. Ask whether every port shares one ``property_package``. - If so, subclass the topology base that matches the port count (``SISOBlock``/``SIDOBlock``/``DIDOBlock``). It already owns port construction and the per-stream mass balance, and the new class only renames the topology's generic roles into its own nomenclature and adds the relationship between flow and energy in ``build()``. To rename, pass a complete ``naming_dict`` up to the base ``build()``. Spread the base's ``_component_names`` and override the subset you're renaming, as :class:`~flexops.unit_models.reverseosmosis.ReverseOsmosis` does, and the base registers it before building anything named. Ports are never renamed. - If the unit needs more than one property package (e.g. a fuel stream and an air stream on different flow bases), subclass :class:`~flexops.core.ops_block.OpsBlockData` directly instead. Declare one named property package config slot per stream family and hand-write the ports and balance across them, rather than forcing a topology base built around a single shared package to fit halfway. - If the unit's **port count is itself a config option** (e.g. an arbitrary number of gas inlets), no topology base with fixed arity fits either. Subclass :class:`~flexops.core.ops_block.OpsBlockData` directly and hand-write the ports and balance, as :class:`~flexops.unit_models.powergeneration.combustor.Combustor`, :class:`~flexops.unit_models.mixer.Mixer`, and :class:`~flexops.unit_models.splitter.Splitter` do. Give each stream its own port. Port members are equalities, so one port carries one arc. N streams mean N ports, never one port fed by N arcs. Topology bases -------------- .. currentmodule:: flexops.unit_models.base.siso .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: SISOBlock .. currentmodule:: flexops.unit_models.base.sido .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: SIDOBlock .. currentmodule:: flexops.unit_models.base.dido .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: DIDOBlock Physical units -------------- .. currentmodule:: flexops.unit_models.pump .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Pump .. currentmodule:: flexops.unit_models.storage.tank .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Tank .. currentmodule:: flexops.unit_models.storage.battery .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: BatteryModel .. currentmodule:: flexops.unit_models.exchanger .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Exchanger .. currentmodule:: flexops.unit_models.reverseosmosis .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: ReverseOsmosis .. currentmodule:: flexops.unit_models.powergeneration.combustor An arbitrary number of fuel sources mix into one flue gas outlet, exporting electrical power (``power_electrical`` upper-bounded at 0, the same sign convention used for battery discharge) under either a heating value relation or a constant intensity relation. The choice resolves automatically based on whether every fuel source was given a heating value. You can connect fuel sources via inlet ports (``inlet_names``), pull them from utilities (``utility_fuel_source``), or both. The relation determines ``power_generated``, the nonnegative magnitude of generation and the unit's registered IO output. The separate, deliberately unregistered ``power_electrical_sign`` constraint then negates it into the draw, so the export convention holds under any surrogate swap. .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Combustor .. currentmodule:: flexops.unit_models.powergeneration.boiler A linear steam boiler with a first-order thermal lag, fired (``BoilerType.FIRED``) or heat recovery (``BoilerType.HEAT_RECOVERY``, with optional duct firing). Fuel enters through inlet ports (``fuel_inlet_names``), from utilities (``utility_fuel_source``), or both. Feedwater enters at ``inlet_feedwater`` and steam leaves at ``outlet_steam``. Steam heat is a thermal export (``power_thermal`` upper-bounded at 0). See :doc:`/explanation/boiler` for the equations and for how to set its parameters from a detailed boiler model. .. autosummary:: :toctree: generated :template: unit_model.rst :nosignatures: Boiler .. autosummary:: :toctree: generated :nosignatures: BoilerType BoilerInletName FiringOption HeatRecoveryOption .. currentmodule:: flexops.unit_models.powergeneration.generic_renewables Like ``Combustor`` and ``BatteryModel``, this unit has no fluid ports (no ``property_package``). It turns an exogenous production profile, whether that's solar irradiance, an output curve derived from wind speed, or any other precomputed capacity factor series, into an electrical export, scaled by a fixable nameplate ``capacity``. Like a discharging ``BatteryModel`` or an exporting ``Combustor``, the draw is negative (export), and the sign is split from the relation for the magnitude of generation the same way ``Combustor`` splits them. With ``curtailable=True`` the optimizer may spill output: ``power_curtailed`` is subtracted from the available ``power_generated`` to give ``power_delivered``, which is what gets exported. By default ``power_curtailed`` is fixed at 0, and every available kWh is exported. .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: GenericRenewables .. currentmodule:: flexops.unit_models.mixer An arbitrary number of named inlet streams join into one outlet at constant density, so volume is conserved directly and no energy is involved. Pressure stays equal across the inlets and passes through to the outlet. The outlet temperature is either equal to the inlets' (the linear default) or a blend weighted by volume, depending on ``temperature_mixing``. .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Mixer .. currentmodule:: flexops.unit_models.splitter One inlet stream divides among an arbitrary number of named outlets at constant density. Conservation is its only flow constraint, so the routing stays a decision variable, with :math:`(N-1)` degrees of freedom per time point that the enclosing model's objective resolves. Use ``SIDOBlock`` instead when you want the split prescribed rather than optimized. .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Splitter .. currentmodule:: flexops.unit_models.wastewater.digestor An anaerobic digester that accepts an arbitrary number of feed streams, each carrying its own property package, and converts them into one biogas outlet and an optional treated sludge outlet. A fixed fraction correlation of the total inlet volume drives biogas volume, and you can replace it with a linear surrogate. .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Digestor .. currentmodule:: flexops.unit_models.electrolyzer An electrolyzer system whose boundary takes in the stack, the gas-liquid separators on both electrode sides, and the electrolyte recirculation loop, so every port carries a single phase. Current density drives it: Faraday's law sets each product's molar rate, cell voltage sets the electrical draw (with an optional quadratic ohmic loss, ``ohmic_loss``), and both gas outlets leave at the fixed operating temperature and pressure. The separators hold a liquid inventory, so make-up water can be fed at a different time from when the stack consumes it. The per-product Faradaic relations and ``power_electrical_relation`` are registered, so you can replace them in place with a fitted Faradaic-efficiency or polarization curve. The anode reaction is a second product table, ``anode_products``, which defaults to oxygen evolution. ``WaterElectrolyzer`` fixes the products to hydrogen and oxygen and takes its defaults from ``technology`` (PEM or AEM). ``CO2Electrolyzer`` takes a product table and adds the CO2 feed, set by single-pass conversion, along with carbonate crossover to the anode and a dissolved fraction of the unreacted CO2. Hydrogen evolution is its ``balance_product`` by default, closing the charge balance, and ``mass_transfer_coefficient`` adds an optional CO2 transport limit. Every gas port builds from ``gas_property_package`` unless it is given its own package (``cathode_gas_property_package``, ``anode_gas_property_package``, or ``co2_property_package``), so each stream can carry a different gas. .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Electrolyzer WaterElectrolyzer CO2Electrolyzer Boundary blocks --------------- .. currentmodule:: flexops.unit_models.feed A source with zero inlets and an arbitrary number of named outlets. It owns a boundary stream (the reference outlet's states other than flow are the boundary conditions, and every other outlet is held at them), meters the total ``withdrawal[t]`` crossing the boundary, optionally bounds it with mutable limit Params, and optionally prices it into opex. Its ``resource_name`` is the key the enclosing plant aggregates it under in ``total_feed[resource, t]``, independent of the block's own Pyomo name. ``withdrawal_basis`` (and ``demand_basis`` on a ``Product``) chooses what the configured limits mean. A rate ceiling and a horizon allowance are different constraints, not two spellings of one. On the default ``"period"`` basis the limit is a **rate** holding in every period (``m**3/hr``), built as a Param over the time index. On the ``"horizon"`` basis it is a **quantity** over the whole horizon (``m**3``), such as a monthly abstraction permit or a take-or-pay contract, bounding a scalar ``withdrawal_total`` defined by ``eq_withdrawal_total`` as :math:`\sum_t withdrawal[t] \cdot dt`. This leaves the optimizer free to shape the profile that reaches it. The metered ``withdrawal[t]`` itself stays indexed by time either way, so costing, plant aggregation and ``set_external_dispatch`` are unaffected. A limit whose units contradict the declared basis raises ``FlexConfigError`` naming the config key. On the period basis a limit may also be a length-T series (or a time-indexed Pyomo component), which sets each period's Param value directly. .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Feed .. currentmodule:: flexops.unit_models.product The mirror sink, with an arbitrary number of named inlets and zero outlets, aggregates what arrives into ``delivery[t]`` and aggregates into ``total_product[resource, t]``. It deliberately does **not** blend. Each inlet's intensive states arrive from its own arc and stay independent, so put a ``Mixer`` upstream when you want a single blended stream. Its price follows the ``register_scalar_cost`` sign convention, where positive is a cost (brine disposal) and negative is revenue (potable water sold). .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: Product .. currentmodule:: flexops.unit_models.grid_connection The plant's point of interconnection with the electric grid. Built directly on a ``PlantBlock`` (anywhere else raises ``FlexConfigError``), it splits the plant's net electrical draw into two non-negative flows, .. math:: P_{import}[t] - P_{export}[t] = P_{plant}[t], where :math:`P_{plant}[t]` is the plant's ``total_electrical_power[t]``, the sum of its units' ``power_electrical``. Generation is negative, so a surplus appears as export. The unit registers no power draw of its own, because it would then count itself in the total it balances. A unit added after the ``GridConnection`` is still included: the constraint references the plant total by name, and ``cost_process()`` refreshes that total in place. ``min_import``/``max_import``/``min_export``/``max_export`` are optional per-period limits, built with the same ``_min``/``_max`` mutable Params and ``_limit`` Constraints as ``Feed`` and ``Product``. ``None`` means unlimited. Each limit is a power scalar, a length-T series, or a time-indexed Pyomo component, so an interconnection limit that varies by hour is given directly. Billing is unchanged: costing still prices the plant's net draw. Nothing prevents importing and exporting in the same period. That is harmless while the two flows share a price, and an exclusivity binary belongs here once export is priced separately. .. autosummary:: :toctree: generated :template: unit_model.rst :nosignatures: GridConnection Generic surrogate ----------------- .. currentmodule:: flexops.unit_models.constant_intensity The default building block for anything without a bespoke physical topology, such as a whole plant modeled as one surrogate, as in the frozen API script. .. autosummary:: :toctree: generated :template: autosummary/unit_model.rst :nosignatures: ConstantEnergyIntensityModel